Specifications & Basic Installation Guidelines

Technical Data...

  • POWER CABLE is direct burial and self sealing.
  • 16/2... cable for runs up to 100 feet.
  • 14/2... cable for runs up to 150 feet.
  • 12/2... cable for runs up to 200 feet.
  • TRANSFORMERS are weatherproof with automatic on & off timers.
  • 88 watt.... handles up to 22 In-Lite modules.
  • 121 watt.. handles up to 30 In-Lite modules.
  • BULBS are 4 watts maximum each with a 5000 hour life expectancy.

Basic Installation Guidelines...

  1. Install transformer at desired location.
  2. Run cable along exposed edges or underneath pavers in the screeded sand bed, where the In-Lite modules are to be placed.
  3. Complete project using standard pavers. After initial compaction, but before sanding, replace standard pavers with In-Lite modules. Connect leads to cable and bury lead underneath the module.
  4. After placing sand on paver project, be careful not to compact directly over the In-Lite modules.
  5. Plug in the transformer and set timers, then enjoy the beauty of your In-Lite project.
..........
..Click a picture to view larger images...